© 2011 Fujitsu Technology Solutions
Severity Level 6
Error Message RADIUS: VENDOR entry invalid on line (<Line Number>) in
dictionary
Explanation An invalid vendor name in dictionary when initiate radius
dictionary.
Recommended Action The name constant config uration need to define again
Severity Level 6
Error Message RADIUS: Vendor Code is invalid on line (<Line Number>) in
dictionary
Explanation An invalid vendor code in dictionary when initiate radius
dictionary.
Recommended Action The Radius module is abnormal.
Severity Level 6
Error Message RADIUS: Unable to register for response callback
Explanation Failed to register for debug user requests callback.
Recommended Action The Radius module is failed to int.
Severity Level 6
Error Message RADIUS: Failed to create socket
Explanation Failed to create socket when open the UDP socket connections
for the RADIUS client.
Recommended Action The Radius module is failed to int.
Severity Level 6
Error Message RADIUS: Bind error
Explanation Failed to socket bind when open the UDP socket connections for
the RADIUS client.
Recommended Action To check between the system and Radius Server, it will be
available or not.
Severity Level 6
Error Message RADIUS: Could not allocate a buffer for the packet
Explanation Could not allocate a buffer for radius packet received.
Recommended Action To check between the system and Radius Server, it will be
available or not.
Severity Level 6
Error Message RADIUS: osapiSocketRecvFrom returned error
Explanation Failed to read the RADIUS response.
Recommended Action The Radius module is failed to int.