EasyManua.ls Logo

Fujitsu PRIMERGY TX1320 M5

Fujitsu PRIMERGY TX1320 M5
407 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Tools: tool-less
Preliminary steps
If the HDD/SSD module to be removed is combined into a RAID array,
proceed as follows:
RAID level
Procedure
RAID 0
CAUTION
RAID 0 provides no data redundancy.
In case of an HDD/SSD module is defect, all data
are lost!
RAID 1
RAID 5
Removing an HDD/SSD module from a RAID 1 or RAID 5
array will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD/SSD module of the same or larger
capacity
.
After replacing the HDD/SSD module, RAID rebuild
will be performed as a background process, see
"Performing a RAID array rebuild" on page 92.
In order to permanently remove an operational HDD/SSD module that is part of
a RAID array from the server, you first need to delete the array using
ServerV
iew RAID Manager.
CAUTION
All data on all HDDs/SSDs in the array will be lost when deleting the
RAID array!
Be sure to back up your data before deleting a RAID array.
For more information, see the "ServerView Suite RAID
Management" user guide.
"Getting access to the component" on page
48.
Hard disk drive (HDD) / solid state drive (SSD)
TX1320 M5 Upgrade and Maintenance Manual 155