Using Infrastructure Manager
The status of server (node) which failed memory module is installed becomes
error.
When replacing the memory module, the status will be updated after getting
information manually or automatically updated daily
.
Proceed as follows to get node information with Infrastructure Manager:
â–¶
Start up the GUI of the Infrastructure Manager and login.
â–¶
Display the node list from menu (manage > node).
â–¶
Select the target node and display the detail screen.
â–¶
Execute getting node information from action menu.
5.3.6.2 Resetting the error status after replacing CPUs
In case of a CPU error, an error counter may be set for the defective CPU.
Important note
After replacing a defective CPU, the error counter must be reset
manually using one of the methods below.
Using ServerV
iew Maintenance Tools (Windows only)
â–¶
Launch the ServerView Maintenance T
ools:
Start > Apps > Fujitsu > Maintenance Tools
â–¶
Choose the CPU status tab.
â–¶
Select the CPU which shows the pre-failure status.
â–¶
Click on Reset Status.
Using the command line (Linux only)
Proceed as follows to reset the error counter of a specific CPU:
â–¶
Log in as root.
Basic software procedures
84 Upgrade and Maintenance Manual TX1320 M5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX1320 M5 and is the answer not in the manual?

Fujitsu PRIMERGY TX1320 M5 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX1320 M5
CategoryServer
LanguageEnglish

Related product manuals