Concluding steps
â–¶
Install the HDD fan modules, see "Installing the HDD fan module (2.5-inch
HDD variant)" on page 68.
â–¶
"Reassembling" on page
54.
â–¶
"Connecting the power cord" on page 57.
â–¶
Update the system information of your server using the Chassis ID Prom
Tool, see "Using the Chassis ID Prom Tool" on page 96. Select the
corresponding system name.
â–¶
"Switching on the server" on page 60.
â–¶
"Performing a RAID array rebuild" on page 92.
7.5.9 Upgrading to 4x PCIe 2.5-inch SSD configuration
A PCIe backplane can only be installed as the first backplane.
A PCIe SSD backplane needs a PRAID EP5x0i or PRAID EP6x0i, see
"Example PRAID EP5xxi" on page
198.
Field Replaceable Unit
(FRU)
Hardware: 10 minutes
Tools: Phillips PH2 / (+) No. 2 screw driver
CAUTION
All data on all HDDs in the array will be lost when deleting the RAID
array!
â–¶
Be sure to back up your data before deleting a RAID array.
â–¶
For more information, see the "ServerView Suite RAID
Management" user guide.
After installing or removing an additional backplane, never forget to
change the system information using the Chassis ID Prom Tool.
Hard disk drive (HDD) / solid state drive (SSD)
168 Upgrade and Maintenance Manual TX1320 M5