Ensure that the two noses of the HDD fan module (see close-up) fit with the
recesses of the HDD cage (see circle).
â–¶
Ensure that the fans freely rotate.
â–¶
Connect the fan cable of HDD fan module 1 to the system board connector
"FAN4 SYS".
â–¶
Connect the fan cable of HDD fan module 2 to the system board connector
"F
AN2 SYS".
4.12.3 Removing the HDD fan module (2.5-inch HDD
variant)
â–¶
Disconnect the corresponding fan cable from the system board.
Figure 24: Removing the HDD fan module
â–¶
Press on the green tab (see circle) and remove the HDD fan module from
the HDD cage.
Basic hardware procedures
TX1320 M5 Upgrade and Maintenance Manual 67