Proceed as follows to get node information with Infrastructure Manager:
â–¶
Start up the GUI of the Infrastructure Manager and login.
â–¶
Display the node list from menu (manage > node).
â–¶
Select the target node and display the detail screen.
â–¶
Execute getting node information from action menu.
5.3.7
Enabling the boot watchdog
If the boot watchdog has been disabled for firmware upgrade purposes (see
"Disabling the boot watchdog" on page
72), it has to be re-enabled to complete
the maintenance task.
Timer settings can be configured in the BIOS or using the iRMC S6 web
interface.
Enabling the boot watchdog in the BIOS
â–¶
Enter the BIOS.
â–¶
Select the Server Mgmt menu.
â–¶
Under Boot Watchdog set the Action setting to Reset.
â–¶
Save your changes and exit the BIOS.
For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
Enabling the boot watchdog using the iRMC S6 web interface
â–¶
Log in to the iRMC S6 web interface.
â–¶
Select the Settings menu.
â–¶
Open the Server Management page.
â–¶
In the Boot W
atchdog group, check the
Enable Boot Watchdog option.
The Enable Boot Watchdog option must be selected.
â–¶
Select Reset from the Watchdog Action list.
â–¶
Click Apply for the changes to take effect.
Basic software procedures
86 Upgrade and Maintenance Manual TX1320 M5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX1320 M5 and is the answer not in the manual?

Fujitsu PRIMERGY TX1320 M5 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX1320 M5
CategoryServer
LanguageEnglish

Related product manuals