Choose the Recovery_L option from the update tool menu to start the iRMC
update process.
CAUTION
If the process is interrupted, the iRMC may be permanently
corrupted.
Do not interrupt the iRMC upgrade process after it has started.
If the iRMC does not work after flashing, disconnect the system from
the mains and reconnect it again.
Shut down the server by pressing the power On/Off button.
Disconnect the server from the mains to exit the iRMC recovery state.
5.3.2
Verifying system information backup or restore
To avoid the loss of non-default settings when replacing the system board, a
backup copy of important system configuration data is automatically stored
from the system board NVRAM to the Chassis ID EPROM. After replacing the
system board the backup data is restored from the Chassis ID board to the
new system board.
In order to verify whether the backup or restore process has been successful,
check the System Event Log (SEL), see "Viewing and clearing the System
Event Log (SEL)" on page 88.
When using the Infrastructure Manager, please refer to the following
manuals about backup and restore function of system information.
See manual "FUJITSU Software Infrastructure Manager
V2.7.0 User's
Guide", section "2.10 Backup/Restore Hardware Settings", available at:
https://ts.fujitsu.com/support/
For Japan:
See manual "FUJITSU Software Infrastructure Manager
V2.7.0 解説書",
section "2.10 ハードウェア設定バックアップ/リストア機能", available at:
https://www.fujitsu.com/jp/products/software/infrastructure-software/
infrastructure-software/serverviewism/technical/
Basic software procedures
78 Upgrade and Maintenance Manual TX1320 M5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX1320 M5 and is the answer not in the manual?

Fujitsu PRIMERGY TX1320 M5 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX1320 M5
CategoryServer
LanguageEnglish

Related product manuals