EasyManuals Logo

Fujitsu PRIMERGY TX1320 M5 User Manual

Fujitsu PRIMERGY TX1320 M5
407 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #159 background imageLoading...
Page #159 background image
Removing the defective 2.5-inch HDD/SSD module
â–¶
Remove the HDD/SSD module, see "Removing 2.5-inch HDD/SSD
modules" on page 154
.
â–¶
If applicable, remove the HDD/SSD from the installation frame, see
"Handling HDDs or SSDs without installation frame" on page 135.
Installing the new 2.5-inch HDD module
â–¶
If applicable, install the HDD/SSD in the installation frame, see "Handling
HDDs or SSDs without installation frame" on page 135.
â–¶
Install the HDD/SSD module, see "Installing 2.5-inch HDD/SSD modules"
on page 152.
Concluding steps
â–¶
If the HDD/SSD is configured using a RAID controller with a RAID level
higher than "0", the rebuild will start automatically, see "Performing a RAID
array rebuild" on page 92.
â–¶
"Reassembling" on page 54.
7.5.7 Replacing a 2.5-inch backplane
Field Replaceable Unit
(FRU)
Hardware: 10 minutes
Tools: Phillips PH2 / (+) No. 2 screw driver
Preliminary steps
If a PCIe backplane should be installed, remove the HDD backplane
from the first place and install it as the second backplane. The PCIe
backplane is always installed as the first backplane.
The HDD backplane is mounted on the HDD cage. It is not necessary to
remove the HDD cage before installing or removing the HDD backplane.
Hard disk drive (HDD) / solid state drive (SSD)
TX1320 M5 Upgrade and Maintenance Manual 159

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX1320 M5 and is the answer not in the manual?

Fujitsu PRIMERGY TX1320 M5 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX1320 M5
CategoryServer
LanguageEnglish

Related product manuals