Removing the defective 2.5-inch HDD/SSD module
Remove the HDD/SSD module, see "Removing 2.5-inch HDD/SSD
modules" on page 154
.
If applicable, remove the HDD/SSD from the installation frame, see
"Handling HDDs or SSDs without installation frame" on page 135.
Installing the new 2.5-inch HDD module
If applicable, install the HDD/SSD in the installation frame, see "Handling
HDDs or SSDs without installation frame" on page 135.
Install the HDD/SSD module, see "Installing 2.5-inch HDD/SSD modules"
on page 152.
Concluding steps
If the HDD/SSD is configured using a RAID controller with a RAID level
higher than "0", the rebuild will start automatically, see "Performing a RAID
array rebuild" on page 92.
"Reassembling" on page 54.
7.5.7 Replacing a 2.5-inch backplane
Field Replaceable Unit
(FRU)
Hardware: 10 minutes
Tools: Phillips PH2 / (+) No. 2 screw driver
Preliminary steps
If a PCIe backplane should be installed, remove the HDD backplane
from the first place and install it as the second backplane. The PCIe
backplane is always installed as the first backplane.
The HDD backplane is mounted on the HDD cage. It is not necessary to
remove the HDD cage before installing or removing the HDD backplane.
Hard disk drive (HDD) / solid state drive (SSD)