CAUTION
▶
Advise your contact persons that they must provide you with all
recovery keys which belong to the system to restore them in the
TPM later.
Preliminary steps
▶
"Locating the defective server" on page 45.
▶
"Suspending BitLocker functionality" on page
99.
▶
"Shutting down the server" on page 47.
▶
"Disconnecting the power cord" on page 48.
▶
"Getting access to the component" on page 50.
▶
Remove the system fan module, see "Removing the system fan module" on
page 82.
▶
If applicable, remove the SAS expander board, see "Removing the SAS
expander board " on page 274.
▶
If applicable, remove the expansion cards, see "Removing an expansion
card" on page 305.
Removing the defective TPM
▶
Remove the TPM, see "Removing the TPM" on page 421.
▶
Leave the TPM spacer on the system board when removing the defective
TPM.
Installing the new TPM
The TPM spacer is already present on the system board.
▶
Install the TPM, see "Installing the TPM" on page 417.
System board and components
426 Upgrade and Maintenance Manual TX1330 M4