EasyManua.ls Logo

Fujitsu PRIMERGY TX1330 M4

Fujitsu PRIMERGY TX1330 M4
565 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CSS indicator (2)
Status Description
off No critical event detected (CSS component).
orange on Prefailure event detected (CSS component).
For HDDs, see also "HDD prefailure detection" on
page
503
.
flashing orange CSS component failure detected.
Global Error indicator (3)
See also "iRMC-related status signals" on page 503.
Status Description
of
f No critical event detected (non-CSS component).
orange on Prefailure event detected (non-CSS component).
flashing orange Non-CSS component failure detected.
Possible causes:
System is out of the specified temperature range
Defective sensor
CPU error
Error detected by server management software
HDD/SSD activity indicator (4)
Status Description
flashing green Data access in progress.
Appendix A
TX1330 M4 Upgrade and Maintenance Manual 501

Table of Contents

Other manuals for Fujitsu PRIMERGY TX1330 M4

Related product manuals