232
Program description - Trim memory | Winged models
Trim memory
Storing the current trim position
This option is available on both transmit-
ter types.
Use the selection keys of the left or right
four-way button to scroll to the »Trim
memory« menu option in the Multi-function menu:
Tx. output swap
Telemetry
Fail-safe adjust
Profi trim
Teacher / pupil
Trim memory
Open this menu option with a tap on the centre SET
key of the right four-way button:
Trim memory
AILE
ELEV
RUDD
0% 0%
0%
0%
0%
POS SET
CH1 0% 0%
0%
This menu permits selective storage of the given cur-
rent position for the four digital trim controls in order to
return them afterward to their visual middle points. This
makes the last stored trim positions in the respective
middle positions of trim levers for control functions 1
… 4 available again following a model memory location
change or after long flight pauses.
The storage of the trim values are-if necessary. Con-
sidering your settings are available in the “Tr” column
of the
mC-20 Hott transmitter only in the menus
»Stick mode” (page 108) “GL (obal)” or “PH (ase)” - in
the »Phase settings« (page 148) and »Phase assign-
ment« menus (page 154) have defined flight phases.
The active flight phase is then also displayed on the
bottom of the display, for example:
Trim memory
AILE
ELEV
RUDD
0% 0%
0%
0%
0%
POS SET
CH1 0% 0%
0%
normal
Storing trim positions
The model has been flight tested and trimmed dur-
ing the test flights. Current trim positions are now
displayed in the column “POS” located approximately
in the middle of the display. (The trim range is about
±30 % of total control travel.) The right column displays
trim memory content, currently filled uniformly with 0 %
because values have not yet been stored. Therefore,
the display appears like as follows:
Trim memory
AILE
ELEV
RUDD
+5% 0%
+3%
0%
–7%
POS SET
CH1 0% 0%
0%
normal
Now use the selection keys on the left or right four-way
button to move to the line where a trim value is to be
written into trim memory, e. g. the elevator trim value:
Trim memory
AILE
ELEV
RUDD
+5% 0%
+3%
0%
–7%
POS SET
CH1 0% 0%
0%
normal
The trim value is stored in the trim memory when you
press the central SET button of the right-hand four-
way button; the setting is displayed in the right-hand
column:
Trim memory
AILE
ELEV
RUDD
+5% 0%
0%
+3%
–7%
POS SET
CH1 0% 0%
0%
normal
Now, if desired, change the flight phase and repeat the
procedure. Perform the same procedure for the other
control functions, as necessary.
Erasing stored trim positions
Use the selection keys on the left or right four-way
button to move to the line where a trim value is to be
erased from trim memory, e. g.:
Trim memory
AILE
ELEV
RUDD
+5% 0%
0%
+3%
–7%
POS SET
CH1 0% 0%
0%
normal
Simultaneously tap on the or selection keys of
the right four-way button (CLEAR) reset the value field
again back to “0 %”.
Trim memory
AILE
ELEV
RUDD
+5% 0%
0%
0%
–7%
POS SET
CH1 0% 0%
0%
normal
However, if you do not erase a trim memo-
ry before storing a new value, the new
value will be added to the stored value.
mc
16 20