1-15 
After completing the above configurations, you can use the following command to view the 
configuration information of the RADIUS scheme named radsun: 
<Switch> display radius scheme radsun 
SchemeName  : radsun 
  Index : 1                            Type : standard 
  Primary Auth IP  : 192.168.1.2      Port : 1812   State : active 
  Primary Acct IP  : 192.168.1.3      Port : 1813   State : active 
  Second  Auth IP  : 192.168.1.3      Port : 1812   State : active 
  Second  Acct IP  : 192.168.1.2      Port :1813    State : active 
  Auth Server Encryption Key : name 
  Acct Server Encryption Key : money 
  Accounting-On packet disable, send times : 5 , interval : 3s 
  Interval for timeout(second)                            : 5 
  Retransmission times for timeout                        : 5 
  Interval for realtime accounting(minute)                : 15 
  Retransmission times of realtime-accounting packet      : 5 
  Retransmission times of stop-accounting packet          : 500 
  Quiet-interval(min)                                     : 5 
  Username format                                         : without-domain 
  Data flow unit                                          : Byte 
  Packet unit                                             : one 
Use the following command to view the configuration information of the ISP domain named sun: 
<Switch> display domain sun 
   Domain = sun 
   State = Active 
   Access-limit = 30 
   Accounting method = Required 
   Default authentication scheme      : radius=radsun 
   Default authorization scheme       : radius=radsun 
   Default accounting scheme          : radius=radsun 
   Domain User Template: 
   Idle-cut = Disabled 
   Self-service = Disabled 
Use the following command to view the port security configuration information: 
<Switch> display port-security interface gigabitethernet 1/0/1 
 Equipment port-security is enabled 
 Trap is disabled 
 Disableport Timeout: 20s 
 OUI value: 
   Index is 1,  OUI value is 123401 
   Index is 2,  OUI value is 123402 
   Index is 3,  OUI value is 123403 
   Index is 4,  OUI value is 123404 
   Index is 5,  OUI value is 123405 
 
 GigabitEthernet1/0/1 is link-up 
   Port mode is userLoginWithOUI