1-3
To do… Use the command… Remarks
Enter system view
system-view
—
Set the time zone
clock timezone zone-name { add | minus }
zone-offset
Optional
clock summer-time zone-name one-off
start-time start-date end-time end-date add-time
Set a daylight saving
time scheme
clock summer-time zone-name repeating
start-time start-date end-time end-date add-time
Optional
Use either command
Displaying the system clock
The system clock is decided by the commands clock datetime, clock timezone and clock
summer-time. If these three commands are not configured, the display clock command displays the
original system clock. If you combine these three commands in different ways, the system clock is
displayed in the ways shown in
Table 1-1. The meanings of the parameters in the configuration column
are as follows:
z 1 indicates date-time has been configured with the clock datetime.
z 2 indicates time-zone has been configured with the clock timezone command and the offset time
is zone-offset.
z 3 indicates daylight saving time has been configured with the clock summer-time command and
the offset time is summer-offset.
z [1] indicates the clock datetime command is an optional configuration.
z The default system clock is 2005/1/1 1:00:00 in the example.
Table 1-1 Relationship between the configuration and display of the system clock
Configuration
System clock displayed by the
display clock command
Example
1
date-time
Configure: clock datetime 1:00 2007/1/1
Display: 01:00:00 UTC Mon 01/01/2007
2
The original system clock ±
zone-offset
Configure: clock timezone zone-time add
1
Display: 02:00:00 zone-time Sat
01/01/2005
1 and 2 date-time ± zone-offset
Configure: clock datetime 2:00 2007/2/2
and clock timezone zone-time add 1
Display: 03:00:00 zone-time Fri
02/02/2007
[1], 2 and 1
date-time
Configure: clock timezone zone-time add
1 and clock datetime 3:00 2007/3/3
Display: 03:00:00 zone-time Sat
03/03/2007
If the original system clock is not in
the daylight saving time range, the
original system clock is displayed.
Configure: clock summer-time ss one-off
1:00 2006/1/1 1:00 2006/8/8 2
Display: 01:00:00 UTC Sat 01/01/2005
3
If the original system clock is in the
daylight saving time range, the
original system clock +
summer-offset is displayed.
Configure: clock summer-time ss one-off
00:30 2005/1/1 1:00 2005/8/8 2
Display: 03:00:00 ss Sat 01/01/2005

Table of Contents

Other manuals for H3C S5120-EI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S5120-EI Series and is the answer not in the manual?

H3C S5120-EI Series Specifications

General IconGeneral
BrandH3C
ModelS5120-EI Series
CategorySwitch
LanguageEnglish

Related product manuals