4.5.4.7 Decoding Channel Properties
The Decoding Channel Properties dialog provides the EMS user the ability to monitor and set-
up the decoding channel properties, arranged in the following groups/panes:
Service Parameters Tab
The Service parameters tab provides the EMS user the following information and set-up
capabilities:
Source box – displays the stream input source and input program name for the decoder.
Service Selection Mode drop-down menu options:
Automatic – Use this mode for ProView 7000 to automatically decode the first
program in the TS (first PMT)
Program – Use this mode to set the decoder to manual program selection
PID – Use this mode to set the decoder to manual PID selection
No Decoding – Use this mode to disable decoding
PID Selection box – Displays the PID for the program PCR and to select the elementry
stream PID for the Video and the VBI/VANC processing. It also enables the user to set
the ES PID and prefered language for each one of the two audio streams (Audio1 and
Audio2).
Channel Descrambling box
Descramble with – Use this feature to enable stream descrambling and to select a
CAM
Program Status – Shows whether the program is being descrambled and by which
CAM slot.