Chapter 4 Element Management System (EMS) Element Properties Configuration
© 2011 Harmonic Inc. 117 ProView 7000 v.2.4, Rev. A
4.5.4.7 Decoding Channel Properties
The Decoding Channel Properties dialog provides the EMS user the ability to monitor and set-
up the decoding channel properties, arranged in the following groups/panes:
Service Parameters Tab
The Service parameters tab provides the EMS user the following information and set-up
capabilities:
■ Source box – displays the stream input source and input program name for the decoder.
❑ Service Selection Mode drop-down menu options:
• Automatic – Use this mode for ProView 7000 to automatically decode the first
program in the TS (first PMT)
• Program – Use this mode to set the decoder to manual program selection
• PID – Use this mode to set the decoder to manual PID selection
• No Decoding – Use this mode to disable decoding
❑ PID Selection box – Displays the PID for the program PCR and to select the elementry
stream PID for the Video and the VBI/VANC processing. It also enables the user to set
the ES PID and prefered language for each one of the two audio streams (Audio1 and
Audio2).
❑ Channel Descrambling box
• Descramble with – Use this feature to enable stream descrambling and to select a
CAM
• Program Status – Shows whether the program is being descrambled and by which
CAM slot.