EasyManua.ls Logo

Honda CM400A - Battery;Charging System

Honda CM400A
317 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HONDA
CBLaQOT
SERVICE INFORMATION 15-1
TROUBLESHOOTING 15-2
BATTERY 15-3
CHARGING SYSTEM 15-5
A.C. GENERATOR
REMOVAL1
INSTALLATION 15-6
SERVICE INFORMATION
a
WORKING PRACTICE
Battery acid level should be checked regularly and filled with distilled water when necessary.
When charging the battery, quick-charging should only be done in an emergency; slow-charging is preferred.
Remove the battery from the motorcycle for charging whenever possible. If battery must be charged on the motorcycle,
disconnect the battery cables.
Keep fire or sparks away from a charging battery because
it
produces hydrogen.
All charging system components can be tested on the motorcycle.
SPECIFICATIONS
Date of Issue: September.
1977
@
HONDA MOTOR CO.. LTD.
12V. 12 ampere-hours (TYPE 1
:
12V,
9
ampere-hours)
TYPE
ll:
1.28, TYPE
I:
1.27/20~~
(138~~)
1.2 amperes maximum (0.9 amperes maximum)
NIGHT:
5 amperes
minimum/5,600 rpm (14.5 volts)
Transistorized non-adjustable regulator
Battery
AC generator
Voltage regulator
Capacity
Specific gravity
Charging rate
Capacity

Table of Contents

Related product manuals