Function Prompt
Selections or Range of
Setting
Parameter Definition
Carbon A Carbon Potential A —Make this
selection if you have a Cambridge or
Marathon monitor type Zirconium
Oxide sensor. See Note 3.
Carbon B Carbon Potential B —Make this
selection if you have a Corning type
Zirconium Oxide sensor. This
algorithm requires a temperature
range within the region of 1380 to
2000°F. See Note 3.
Carbon C Carbon Potential C —Make this
selection if you have an A.A.C.C. type
Zirconium Oxide sensor. This
algorithm requires a temperature
range within the region of 1380 °F
to 2000 °F. See Note 3.
Carbon D Carbon Potential D —Make this
selection if you have a Barber
Coleman, MacDhui, or Bricesco type
Zirconium Oxide sensor. This
algorithm requires a temperature
range within the region of 1380 to
2000°F. See Note 3.
Carbon FCC
Carbon Potential FCC —Make this
selection if you have a Furnace
Controls Corp Accucarb type
Zirconium Oxide sensor. This
algorithm requires a temperature
range within the region of 1380 °F
to 2000 °F. See Note 3.
Dewpoint Dewpoint of Carbonizing
Atmosphere —Use this selection if
you are using any Zirconium Oxide
Carbon Probe and you want to
measure the atmosphere in terms of
Dewpoint. The range is –50 °F to
100 °F or –48 °C to 38 °C. This
algorithm requires a temperature
105
Chapter 4 - Configuration