Digital Input Register Map
Use the identifying codes listed in the following table to read the
specific items.
A Write request for these codes will result in an Error message.
Table 12-4: Digital Input Parameters
Parameter Description
Register Address
Data
Type
Access Description
Hex Decimal
Digital Input 1 0x0000 10001 Coil R 0: No input
1: Digital
Input 1
Digital Input 2 0x0001 10002 Coil R 0: No input
1: Digital
Input 2
Loop Value Integer Register Map
Table 12-5: Loop Value Integer Register Map
Parameter Description
Register Address
Access Description
Hex Decimal
PV 0000 40001 R Signed 16 bit
integer, prescale *
10 ( Note 1)
RV; Remote Set Point
SP2
0001 40002 R Signed 16 bit
integer, prescale *10
Working Set Point 0002 40003
R/W Signed 16 bit
integer, prescale *
10 ( Note 1)
Output 0003 40004
R/W Signed 16 bit
integer, prescale *
10
Input #1 0004 40005
R Signed 16 bit
Chapter 12 - Standard Modbus Read, Write and Override Parameters