Loading...
5. Minimum R Channel Level
Specifications
1
Frequency Range
1
Minimum
B
Channel Level
1
1300kHzto3GHz
1
c-35
dBm
I
13GHzto6GHzl
1
c-30
dBm
I
1OnlyforanalyzerswithOption006-3OkHzto6GHz
range.
Required Equipment for 500 Analyzers
Adapter,
APC-3.5
(m) to
APC-7
. . . . . . . . . . . . . . . . . . . , . . . . . . . . . . HP P/N 1250-1746
Cable, APC-7
24-inch
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HP P/N 8120-4779
Required Equipment for 75 ohm Analyzers (Option 075)
Minimum Loss Pad,
5OQ
to
75Q
. . . . . , . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HP
11852B
Cable,
508
Type-N,
24-inch
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .HP P/N 8120-4781
Adapter,
APC-3.5
(m) to Type-N
(f)
. . . . . . . . . . . . . . . . . . . . . . . . . . HP P/N 1250-1750
An&m
warmup
time:
1
hour
Perform this test to determine the minimum R channel input power level at
which phase lock can be accomplished.
1. Connect the equipment as shown in Figure 2-12.