EasyManuals Logo

Juniper BTI7800 Series User Manual

Juniper BTI7800 Series
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
Table 10: BTI7814 Chassis Specifications (continued)
SpecificationShell
GR-1089
GR-3160 (basic temperature range)
NEBS
BTI7802 Chassis
The BTI7802 chassis has 2 universal slots that can be individually equipped with
traffic-carrying service modules. The BTI7802 can be installed into 19-inch, 23-inch, and
ETSI 600-mm racks.
The BTI7802 supports redundant management modules, AC and DC power options, and
service modules for high availability.
The chassis provides front access for all components:
One slot for the cooling module
Two slots for service modules
Two slots for redundant Chassis Management Modules
Two slots for redundant PEM modules
One slot for the Chassis Alarm Panel
Figure 5: BTI7802 Chassis Front View
The following table lists the common equipment for the BTI7802 chassis:
Table 11: BTI7802 Common Equipment Components
Release IntroducedPECComponent
Release 1.3BT8A78CAP22-Slot Chassis Alarm Panel
Release 1.6BT8A78FAN22-Slot Chassis Cooling Module
Release 1.3BT8A78PEM1-DC1-Slot/2-Slot Chassis DC Power Entry Module
Release 1.3BT8A78PEM1-AC1-Slot/2-Slot Chassis AC Power Entry Module
Copyright © 2019, Juniper Networks, Inc.34
BTI7800 Series Hardware Overview and Installation Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper BTI7800 Series and is the answer not in the manual?

Juniper BTI7800 Series Specifications

General IconGeneral
BrandJuniper
ModelBTI7800 Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals