Table 10: BTI7814 Chassis Specifications (continued)
SpecificationShell
GR-1089
GR-3160 (basic temperature range)
NEBS
BTI7802 Chassis
The BTI7802 chassis has 2 universal slots that can be individually equipped with
traffic-carrying service modules. The BTI7802 can be installed into 19-inch, 23-inch, and
ETSI 600-mm racks.
The BTI7802 supports redundant management modules, AC and DC power options, and
service modules for high availability.
The chassis provides front access for all components:
One slot for the cooling module
Two slots for service modules
Two slots for redundant Chassis Management Modules
Two slots for redundant PEM modules
One slot for the Chassis Alarm Panel
Figure 5: BTI7802 Chassis Front View
The following table lists the common equipment for the BTI7802 chassis:
Table 11: BTI7802 Common Equipment Components
Release IntroducedPECComponent
Release 1.3BT8A78CAP22-Slot Chassis Alarm Panel
Release 1.6BT8A78FAN22-Slot Chassis Cooling Module
Release 1.3BT8A78PEM1-DC1-Slot/2-Slot Chassis DC Power Entry Module
Release 1.3BT8A78PEM1-AC1-Slot/2-Slot Chassis AC Power Entry Module