Figure 11: BTI7802 1-Slot/2-Slot Chassis DC Power Entry Module
If a seated DC PEM is not connected to a power feed, but the chassis is otherwise powered
(by the other PEM), the following occurs:
•
The unpowered DC PEM is shown in inventory.
•
The red LED on the unpowered DC PEM is illuminated.
•
A powerAbsent alarm is raised for the unpowered DC PEM.
BTI7802 DC PEM Specifications
Table 20: BTI7802 1-Slot/2-Slot Chassis DC Power Entry Module (BT8A78PEM1-DC) Specifications
SpecificationItem
Physical Dimensions
85 mm3.35 inWidth
40.5 mm1.59 inHeight
305 mm12.00 inDepth
0.7 kg1.60 lbWeight
99.9% efficient (maximum 20W)Power Consumption (40°
ambient)
NOTE: Before using for
planning or implementation
purposes, contact Juniper
Networks Support to confirm
the power consumption values.
1000 WPower Capacity
49Copyright © 2019, Juniper Networks, Inc.
Chapter 2: BTI7800 Series Chassis