EasyManua.ls Logo

Juniper EX2200 - Page 277

Juniper EX2200
354 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cable status : Normal
Distance fault : 0 Meters
Polartiy swap : Normal
Skew time : 8 ns
MDI pair : 4-5
Cable status : Normal
Distance fault : 0 Meters
Polartiy swap : Normal
Skew time : 8 ns
MDI pair : 7-8
Cable status : Normal
Distance fault : 0 Meters
Polartiy swap : Normal
Skew time : 8 ns
Channel pair : 1
Pair swap : MDI
Channel pair : 2
Pair swap : MDI
Downshift : No Downshift
show diagnostics tdr interface ge-2/0/2 (Faulty Cable)
user@switch> show diagnostics tdr interface ge-2/0/2
Interface TDR detail:
Interface name : ge-2/0/2
Test status : Passed
Link status : Down
MDI Pair : 1-2
Cable status : 1-2
Distance fault : 2 Meters
Polartiy swap : N/A
Skew time : N/A
MDI Pair : 3-6
Cable status : Impedance Mismatch
Distance fault : 3 Meters
Polartiy swap : N/A
Skew time : N/A
MDI Pair : 4-5
Cable status : Impedance Mismatch
Distance fault : 3 Meters
Polartiy swap : N/A
Skew time : N/A
MDI Pair : 7-8
Cable status : Short on Pair-2
Distance fault : 3 Meters
Polartiy swap : N/A
Skew time : N/A
Channel pair : 1
Pair swap : N/A
Channel pair : 2
Pair swap : N/A
Downshift : N/A
show diagnostics tdr (All Supported Interfaces)
user@switch> show diagnostics tdr
Interface Test status Link status Cable status Max distance fault
ge-0/0/0 Not Started N/A N/A N/A
ge-0/0/1 Not Started N/A N/A N/A
ge-0/0/2 Started N/A N/A N/A
ge-0/0/3 Started N/A N/A N/A
257Copyright © 2015, Juniper Networks, Inc.