Table 35: Alarms for Services Gateway Chassis Components (continued)
Alarm SeverityActionAlarm ConditionsComponent
Red (major)Contact JTAC.A GPIM has failed.Gigabit-Backplane
Physical Interface
Module (GPIM)
Yellow (minor)
Check the room
temperature. See
“SRX650 Services
Gateway Environmental
Specifications” on
page 42.
Check the air flow. See
“SRX650 Services
Gateway Cabinet
Airflow Requirements”
on page 52.
Check the fans. See
“Maintaining the
SRX650 Services
Gateway Cooling
System Components”
on page 124.
If you must replace a
fan, contact JTAC.
The services gateway
chassis temperature
is too warm.
Hardware
components on
services gateway
Red (major)Place your hand near the
exhaust vents at the rear
of the chassis to determine
whether the fan is pushing
air out of the chassis.
Replace the failed fan and
contact JTAC.
The services gateway
fan has failed.
NOTE: For more information about alarms, see the Monitoring and
Troubleshooting for Security Devices.
Related
Documentation
Troubleshooting with the CLI on the SRX650 Services Gateway on page 125
SRX650 Services Gateway Front Panel on page 18
SRX650 Services Gateway Back Panel on page 24
Troubleshooting the Power System on the SRX650 Services Gateway on page 132
Using the RESET CONFIG Button on the SRX650 Services Gateway on page 135
Changing the RESET CONFIG Button Behavior on the SRX650 Services Gateway on
page 136
131Copyright © 2018, Juniper Networks, Inc.
Chapter 21: Troubleshooting Components