Preparing the SRX650 Services Gateway for Rack-Mount Installation
You can mount an SRX650 Services Gateway on four-post (telco) racks, enclosed
cabinets, and open-frame racks. Center-mount racks are not supported.
Before mounting the SRX650 Services Gateway in a rack:
•
Verify that the site meets the requirements described in “Site Preparation Checklist
for the SRX650 Services Gateway” on page 39.
•
Verify that you have the following parts available in your rack-mounting kit for the
SRX650 Services Gateway:
•
Rack-mounting brackets
•
Screws
•
Verify that the racks or cabinets meet the specific requirements described in “SRX650
Services Gateway Rack Size and Strength Requirements” on page 47.
•
Place the rack or cabinet in its permanent location, allowing adequate clearance for
airflow and maintenance, and secure it to the building structure. For more information,
see “SRX650 Services Gateway Cabinet Airflow Requirements” on page 52.
•
Remove the gateway chassis from the shipping carton. For unpacking instructions, see
“Unpacking the SRX650 Services Gateway” on page 65.
Related
Documentation
SRX650 Services Gateway Cabinet Size and Clearance Requirements on page 51•
• Installation Overview for the SRX650 Services Gateway on page 63
Connecting the SRX650 Services Gateway to the Building Structure
Always secure the rack in which you are installing the SRX650 Services Gateway to the
structure of the building. If your geographical area is subject to earthquakes, bolt the rack
to the floor. For maximum stability, also secure the rack to ceiling brackets.