NOTE: In North America, AC power cords must not exceed 4.5 m
(approximately 14.75 ft) in length, to comply with National Electrical code
(NEC) Section 400-8 (NFPA 75, 5-2.2) and 210-52, and Canadian Electrical
Code (CEC) Section 4-010(3).
Table 14 on page 55 provides power cord specifications, and Figure 12 on page 55 depicts
the plug on the AC power cord provided for each country or region.
Table 14: AC Power Cord Specifications
Plug StandardsElectrical SpecificationCountry
AS/NZ 3112-1993250 VAC, 10 A, 50 HzAustralia
GB2099.1 1996 and
GB 1002 1996
(CH1-10P)
250 VAC, 10 A, 50 HzChina
CEE (7) VII250 VAC, 10 A, 50 HzEurope (except Italy and United Kingdom)
CEI 23-16/VII250 VAC, 10 A, 50 HzItaly
JIS 8303125 VAC, 12 A, 50 or 60 HzJapan
NEMA 5-15125 VAC, 10 A, 60 HzNorth America
BS 1363A250 VAC, 10 A, 50 HzUnited Kingdom
Figure 12: AC Plug Types
NOTE: Power cords and cables must not block access to services gateway
components or drape where people might trip on them.
Related
Documentation
SRX650 Services Gateway Power Supply on page 33•
• Clearance Requirementsfor Airflow and Hardware Maintenance of the SRX650 Services
Gateway on page 48
• SRX650 Services Gateway Electrical Wiring Guidelines on page 53
• Site Preparation Checklist for the SRX650 Services Gateway on page 39
55Copyright © 2018, Juniper Networks, Inc.
Chapter 10: Power Requirements and Specifications

Table of Contents

Other manuals for Juniper SRX650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper SRX650 and is the answer not in the manual?

Juniper SRX650 Specifications

General IconGeneral
BrandJuniper
ModelSRX650
CategoryGateway
LanguageEnglish

Related product manuals