set the rescue configuration through J-Web or the CLI. The rescue configuration is a
previously committed, valid configuration.
CAUTION: Pressing and holding the RESET CONFIG button for 15 seconds
or more—until the STATUS LED blinks red—deletes all configurations on the
services gateway, including the backup configurations and rescue
configuration, and loads and commits the factory configuration.
There are two types of reset:
•
Power On—This reset occurs during the services gateway powering on and powering
off. This reset is issued when the services gateway is first powered on. The system
accesses the configuration settings from the boot flash for this type of reset.
•
Config—This reset is the asynchronous reset input to the services gateway. The RESET
CONFIG button is used to generate a reset to load the default configuration settings
from the kernel. The system accesses the default factory settings from the internal
flash for this type of reset.