Pilot’s Operating Handbook
3-6
DO NOT USE FOR FLIGHT OPERATIONS
Section 3
EMERGENCY PROCEDURES
100 SERIES
Emergency
Engine Flameout During Flight
If
Ng
is above 52%:
1. Power Lever ..........................................................................................IDLE
2. Ignition Switch
.........................................................................................ON
3. Power Lever........................................................................... AS REQUIRED
(Following successful relight as indicated by normal ITT and
Ng
.)
4. Ignition Switch........................................................................ AS REQUIRED
(Shut off, if cause of ameout has been eliminated.)
If
Ng
is below 52%:
1. Fuel Condition Lever ......................................................................CUTOFF
2. Refer to the Airstart checklist for engine restart.
Uncontrolled if printed