Pilot’s Operating Handbook
3-7
DO NOT USE FOR FLIGHT OPERATIONS
Section 3
EMERGENCY PROCEDURES
100 SERIES
Emergency
AIRSTART
Starter Assisted Airstart (Preferred Method)
1. Electrical Load .................................................................................REDUCE
2. Generator Switch
..................................................................................... OFF
3. Alternator Switch......................................................................................OFF
4. AUX BUS Switch
.....................................................................................OFF
5. Emergency Power Lever
.................................................................NORMAL
6. Power Lever............................................................................................ IDLE
7. Propeller Control Lever
..................................................AT LOW RPM STOP
8. Fuel Condition Lever.........................................................................CUTOFF
9. Firewall Fuel Shutoff
...................................................................ON (push in)
10. Fuel Selector Valves
.......................................................................BOTH ON
11. Master Switch
............................................................................................ON
12. Auxiliary Fuel Pump
................................................................................... ON
Ensure the AUX PUMP ON annunciation is shown on the PFD.
13. Altitude
..........................................................................16,000 feet maximum
14. Starter Switch
......................................................................... HI START and:
Ensure the IGNITION ON annunciation is shown on the PFD.
Ensure the engine oil pressure is rising.
Ng
to 14% minimum.
15. Fuel Condition Lever......................................................................LOW IDLE
Check ITT (1090°C maximum)
Check
Ng
(50% minimum)
16. Starter Switch ..........................................................................................OFF
17. Ignition Switch........................................................................ AS REQUIRED
18. Fuel Condition Lever..................................................................... HIGH IDLE
19. Propeller Control Lever
............................................................. AS DESIRED
20. Power Lever.............................................................................. AS DESIRED
21. Auxiliary Fuel Pump
............................................................................... STBY
If AUX pump cycles on and off, leave the AUX fuel pump ON.
22. Generator Switch
.......................................................................................ON
23. Alternator Switch........................................................................................ON
24. Electrical Equipment
.............................................................. AS REQUIRED
WARNING: If operating with nearly empty fuel tanks or in heavy
precipitation, turn the ignition switch ON.
Uncontrolled if printed

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kodiak 100 Series and is the answer not in the manual?

Kodiak 100 Series Specifications

General IconGeneral
ManufacturerDaher
EnginePratt & Whitney Canada PT6A-34
Service Ceiling25, 000 feet
Seating Capacity10
Crew1-2
Range1, 132 nautical miles
TypeUtility aircraft
Length34 feet 2 inches
Wingspan45 feet
Max takeoff weight7, 255 pounds
Power Output750 shp
Cabin Width4 feet 6 inches