EasyManua.ls Logo

Kodiak 100 Series - Airstart

Kodiak 100 Series
606 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pilot’s Operating Handbook
3-7
DO NOT USE FOR FLIGHT OPERATIONS
Section 3
EMERGENCY PROCEDURES
100 SERIES
Emergency
AIRSTART
Starter Assisted Airstart (Preferred Method)
1. Electrical Load .................................................................................REDUCE
2. Generator Switch
..................................................................................... OFF
3. Alternator Switch......................................................................................OFF
4. AUX BUS Switch
.....................................................................................OFF
5. Emergency Power Lever
.................................................................NORMAL
6. Power Lever............................................................................................ IDLE
7. Propeller Control Lever
..................................................AT LOW RPM STOP
8. Fuel Condition Lever.........................................................................CUTOFF
9. Firewall Fuel Shutoff
...................................................................ON (push in)
10. Fuel Selector Valves
.......................................................................BOTH ON
11. Master Switch
............................................................................................ON
12. Auxiliary Fuel Pump
................................................................................... ON
Ensure the AUX PUMP ON annunciation is shown on the PFD.
13. Altitude
..........................................................................16,000 feet maximum
14. Starter Switch
......................................................................... HI START and:
Ensure the IGNITION ON annunciation is shown on the PFD.
Ensure the engine oil pressure is rising.
Ng
to 14% minimum.
15. Fuel Condition Lever......................................................................LOW IDLE
Check ITT (1090°C maximum)
Check
Ng
(50% minimum)
16. Starter Switch ..........................................................................................OFF
17. Ignition Switch........................................................................ AS REQUIRED
18. Fuel Condition Lever..................................................................... HIGH IDLE
19. Propeller Control Lever
............................................................. AS DESIRED
20. Power Lever.............................................................................. AS DESIRED
21. Auxiliary Fuel Pump
............................................................................... STBY
If AUX pump cycles on and off, leave the AUX fuel pump ON.
22. Generator Switch
.......................................................................................ON
23. Alternator Switch........................................................................................ON
24. Electrical Equipment
.............................................................. AS REQUIRED
WARNING: If operating with nearly empty fuel tanks or in heavy
precipitation, turn the ignition switch ON.
Uncontrolled if printed

Table of Contents