12 Terminal machine functions
12.7 Operating TIM 1.0 (Tractor Implement Management)
110
Comprima V 180
Original Operating Instructions 150001053_00_en
• registration and authentication were run on the tractor.
ü The TIM status on the working screen is on .
Press
.
Confirm the TIM functions on the terminal or on another control panel on the tractor.
Æ The TIM status switches to . The machine automatically takes over control of the
TIM functions on the tractor.
If no TIM status is displayed on the working screen, the TIM functions must be selected and
registered and authenticated via menu 14-5 "Configuring TIM software", refer to page129.
INFORMATION
In the case of the TIM function "Stop tractor when the tying cycle starts", the tractor must be
driven at a speed of at least 0.5km/h before the TIM function can be confirmed on the tractor.
INFORMATION
If 2TIM functions are active and one of them is overridden, the TIM status flashes.
If only one TIM function is active and is overridden, the TIM status switches to
To restore the connection, press the key
.
12.7.4 Pausing TIM functions
If TIM is not to be used for the time being, TIM can be paused. In doing so, registration and
authentication are retained between tractor and machine.
ü The TIM status on the working screen is on .
Press
.
Æ The TIM functions are paused and must be operated manually via the tractor control units.
The TIM status switches to .
To reactivate the TIM functions, refer to page109.