17 Malfunction, cause and remedy
17.2 Disturbances during or after the baling process
196
Comprima V 180
Original Operating Instructions 150001053_00_en
Possible cause Remedy
The density of the bale core
has been set too solid.
Adjust the density of the bale core, refer to page147.
If required, reduce the baling pressure.
17.2 Disturbances during or after the baling process
Malfunction: The bale formation conveyor is rotating slower than it should. Slippage is
occurring.
Possible cause Remedy
The baling pressure is too
high.
Reduce the baling pressure, refer to page146.
The rotational speed is too
high.
Reduce the rotatonal speed.
The sensor B01 "Speed of
bale chamber" is defective.
Check the sensor and the cabling for damage, refer to
page202.
The crops consist of very
heavy grass without structure
(e.g. clover grass).
Reduce the density of the bale core, refer to page147.
Have the KRONE service partner install an additional drive.
The additional drive can be ordered by quoting order number
20063652*.
Malfunction: Pressure does not build up.
Possible cause Remedy
The handwheel for setting the
baling pressure is in the park-
ing position.
Turn the handwheel to the working position, refer to
page146.
Set the required baling pressure on the handwheel, refer to
page146.
Disturbance: The round bale does not roll or rolls just slowly out of the bale chamber.
Possible cause Remedy
The sides are filled excess-
ively.
Produce narrower swaths, refer to page66.
Do not drive too far on the side.
The baling pressure is too
high.
To reduce the baling pressure, refer to page146.
Malfunction: The machine is running unevenly and the baling process in the bale chamber is
difficult to start.
Possible cause Remedy
The density of the bale core is
too high.
Reduce the density of the bale core, refer to page147.
Reduce the baling pressure, refer to page146.
Malfunction: The hydraulic oil has become too hot.
Possible cause Remedy
The hydraulic oil filter is
blocked.
Change the hydraulic oil filter, refer to page194.
Disturbance: The tailgate cannot be closed completely.