13 Terminal menus
13.20 Menu 15 "Settings"
134
Comprima V 180
Original Operating Instructions 150001053_00_en
No. Sensor Designation
B01
Speed of bale chamber
B02
Tying process active
B05
Slip floor conveyor
B06
Twine tying cycle active
B09
Filling display left
B10
Filling display right
B11
Lock hook bale chamber left
B12
Lock hook bale chamber right
B61
Tying 1 (passive)
Possible status displays of the sensors
Icon Designation
0
Sensor ready to operate
1
Sensor attenuated (metal in front of the sensor)
2
Sensor unattenuated (no metal in front of the sensor)
7
Cable break or short circuit
8
Defect in sensor or job computer
20 Cable break
21
Short circuit