17 Malfunction, cause and remedy
17.5 Faults of the electrics/electronics
204
Comprima V 180
Original Operating Instructions 150001053_00_en
521100-
High
Voltage group (UB1) of the KRONE Machine Controller (KMC)
Possible cause Remedy
FMI 3: An overvoltage or a short circuit to the supply voltage has occurred.
The cabling is faulty.
Check the cabling for damage, refer to page202.
One or several sensors/actu-
ators connected to the voltage
group are defective.
An overview of the position of the sensors, actuators and
control units is provided in the circuit diagram, refer to
page231.
Check the sensor and cabling for damage, refer to
page202.
The control unit KMC is de-
fective.
Replace the control unit KMC.
Note the error number with the FMI and contact the KRONE
service partner.
521100-
Low
Voltage group (UB1) of the KRONE Machine Controller (KMC)
Possible cause Remedy
FMI 4: An undervoltage or a short circuit to ground has occurred.
The cabling is faulty.
Check the cabling for damage, refer to page202.
One or several sensors/actu-
ators connected to the voltage
group are defective.
An overview of the position of the sensors, actuators and
control units is provided in the circuit diagram, refer to
page231.
Check the sensor and cabling for damage, refer to
page202.
The control unit KMC is de-
fective.
Replace the control unit KMC.
Note the error number with the FMI and contact the KRONE
service partner.
521100-
High
Voltage group (UB1) of the KRONE Machine Controller (KMC)
Possible cause Remedy
FMI 5: A cable break has occurred or the current intensity is too weak.
The cabling is faulty.
Check the cabling for damage, refer to page202.
One or several sensors/actu-
ators connected to the voltage
group are defective.
An overview of the position of the sensors, actuators and
control units is provided in the circuit diagram, refer to
page231.
Check the sensor and cabling for damage, refer to
page202.
The control unit KMC is de-
fective.
Replace the control unit KMC.
Note the error number with the FMI and contact the KRONE
service partner.