Malfunction, cause and remedy 17
Faults of the electrics/electronics 17.5
Comprima V 180
Original Operating Instructions 150001053_00_en 219
Possible cause Remedy
FMI 2: The tailgate is open while starting up the machine.
The tailgate is not locked.
Close the tailgate using the tractor hydraulics.
The sensor is defective or has
been incorrectly set.
Check and set the sensorsB11/B12 “Lock hook bale
chamber left/Lock hook bale chamber right”, refer to
page133.
522048-
Tailgate
Possible cause Remedy
FMI 2: – The tailgate is open during road operating mode.
The tailgate is not locked.
Close the tailgate using the tractor hydraulics.
The sensor is defective or has
been incorrectly set.
Check and set the sensorsB11/B12 “Lock hook bale
chamber left/Lock hook bale chamber right”, refer to
page202.
522049-
Tailgate
Possible cause Remedy
FMI 2:An open tailgate was detected, although no tying has occurred since it was last closed.
The baling pressure is too
high.
Start net or chamber film wrapping in manual mode and tie
the round bale.
For "Net wrapping" version: refer to page124
For "Net and chamber film wrapping" version: refer to
page125
The bale chamber is overfilled
so that it was opened by the
bale.
Manually empty the bale chamber.
The tailgate is not correctly
locked.
Open and close the tailgate again.
522101-
SensorB01 “Speed of bale chamber”
Possible cause Remedy
FMI 4: An undervoltage or a short circuit to ground has occurred.
FMI 5: A cable break has occurred or the current intensity is too weak.
The sensor shows external
damage.
Check sensor and wiring for damage, refer to page202.
The wiring of the sensor is de-
fective.
522102-
SensorB02 "Tying process active"