6.14.1 Menu 4-2 "Manual Sensor Test"
SW2000074
4-2
SW2000045
2
B 1
B 2
OFF
ON
Fig. 54
In the manual sensor test, the sensors that are installed on the machine are checked for errors.
In addition, the sensors can be correctly adjusted in the manual sensor test. There is no
guarantee the machine is working correctly until after the sensors have been adjusted.
CAUTION!
The PTO must not be turning during the sensor test.
Calling the Menu
Main menu 4 "Service" is called.
• You can select menu 4-2 with the rotary potentiometer. The icon is displayed
inversely
• Press the rotary potentiometer
The display shows menu 4-2 "Manual sensor test"
Selecting the sensor
• Select the sensor with the rotary potentiometer
The selected sensor is displayed inversely and is tested.
Pos: 16.24.34 / BA/Info-Center/S ensoren/Diagnos eN amursensor en @ 19\mod _123807212530 0_78.doc @ 21 4095 @ @ 1
Diagnostics – Namur sensors
Pos: 16.24.35 / BA/Info-Center/Sc hwader/Bedie neinheit - Komf ort/Swadro 1400 /Hauptmenüs/H auptmenü 4 S ervice/Einstellwert e Sensor allgem einer Text @ 6\ mod_121541 6779856_78.doc @ 101137 @ @ 1
Setting values:
The minimum and maximum setting values with the sensor alive (metal in front of the sensor)
are shown in the upper part of the bar display. The current setting value (actual value) is
displayed under the bar display.
The distance from the sensor to the metal must be adjusted so that in the alive state the bar is
in the upper mark. Next check whether the bar is in non-alive state in the lower marked area.
Pos: 16.24.36 / BA/-----Seitenu mbruch------ @ 0\ mod_11961753 11226_0.doc @ 4165 @ @ 1