KRONE ISOBUS-Terminal CCI 100
168
Pos: 22.5.83 /B A/Info-Center/Sch wader/Bedi eneinheit - Komfort /Swadro 1400/ Alarmmeldung/ Allgemeine Al armmeldungen T abelle SW 2000 @3 6\mod_126 3292130184_78.d oc @ 338667 @ 23 @ 1
8.16 Alarm messages
8.16.1 General alarms
No. Screen Description Possible cause Remedy
A1 Plug-in fuse in
job computer
defective
Short circuit at electrical outputs
+12V2FU_L
Check the
connection for short
circuit and replace
fuse
A2 Fuse in job
computer
defective
Short circuit at electrical outputs
+12V3FU_L
Check the
connection for short
circuit. The fuse
resets itself after the
unit has cooled down
A03 CAN error The CAN bus was interrupted
between the control unit and the
machine. -> loose contact in the
connection to the display
Check the display
line
A05
CAN connection
to IO module
interrupted
The CAN bus between the main
computer and the IO unit is
interrupted
Check CAN cabling
A06
A07
A14 Undervoltage - Tractor battery defective
- Tractor dynamo too weak
- 12-V power supply too weak on
the tractor side or not correctly
connected with the battery
Connect the KRONE
connection cable to
the tractor battery
A15 Overvoltage Tractor dynamo defective Check dynamo
Pos: 22.5.84 /B A/-----Seitenum bruch------ @ 0\m od_119617531 1226_0.doc @ 4 165 @ @ 1