3-14 824 Reference Manual 11/8/00
To move from one record to another,
use the
u
or
d
keys.
To exit the Data Files view, press the
l
to return to the previous display
or select a new view using the
V
VIEW key.
Pressing the
c
key from the Data
Files display, brings up a menu that
allows you to recall data, jump to
beginning or end of all records, find
a specific data file, or purge all data
files.
The
Data Files
screen shows the currently selected record
number (
1/4
), start & stop dates and times, and the total
bytes used by the record.
Pressing the
c
key and selecting
Recall File
from the
Data
Files
menu, allows you to recall that measurement. An
active data display will be shown.
When recalling a data file, the System 824 will switch to the
instrument definitions (ID) that the data file was stored as
(i.e. SLM&RTA to Logging, if the user was currently using
the SLM&RTA instrument and recalled a Logging data file).
If the run key
s
is pressed while a recalled data file is
active, the data is reset and the new data is taken using all of
the settings that were stored with that data file.
The data file also contains calibration information that is dif-
ferent than the current calibration. When Run is pressed, the
recalled calibration is replaced by the latest /current calibra-
tion.
S
Setup Key
To the left of each ID is a symbol giv-
ing information about that ID: The
‘>’ symbol indicates that the ID is
currently active or that the ID is cur-
rently in memory.
The lock symbol indicates that the ID
is locked which protects the ID from
being easily deleted.
The ‘p’ symbol indicates that the ID
is permanent and pre-defined.
The ’
*
’ symbol indicates that the ID
has changed and hasnot yet been
saved.
Use the
S
SETUP key to access the
Setup
menu where you
can select, create, and manipulate groups of instrument set-
tings known as “instrument definitions” (ID). The
Setup
menu presents a list of pre-defined IDs (marked with a “p”)
and user-defined IDs (if previously configured) that are
available for use. To access the
Setup
menu, press the
S
key. A screen similar to this appears:
An ID defines the data that is to be measured for a particular
project or type of application. The defined project IDs are
listed in the
Setup
menu. You can create, edit, copy, and
delete these project settings within this menu. You can also

Table of Contents

Other manuals for Larson Davis System 824

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Larson Davis System 824 and is the answer not in the manual?

Larson Davis System 824 Specifications

General IconGeneral
BrandLarson Davis
ModelSystem 824
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals