8.2.3 Lenze LECOM prole
For connecon to Lenze inverters with a LECOM control word (C135) and LECOM status word
(C150), the parameters lis
ted in the following can be mapped to network registers.
Details
•
The LECOM contr
ol word (C135) features the mapping address 0x400B0200.
•
The LECOM status word (C150) features the mapping address 0x400C0200.
•
General informaon about the process of data mapping can be found in the chapter of the
same name for the corresponding netw
ork.
Parameter Name / value range / [default seng] Info
0x400B:002
(PAR 592/002)
Predened process input data
: LECOM control word
(C135)
(Legacy NetWordIN: C0135 control word)
0x0000 ... [0x0000] ... 0xFFFF
Mappable control word with bit assignment in compliance with code
C135 of the 8200 Lenze inverter.
Bit 0 Setpoint Selecon bit 0
Bit 1 Setpoint Selecon bit 1
Bit 2 Reversal
Bit 3 Quick stop
Bit 4 Reserved
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9 Controller inhibit
Bit 10 User-dened fault
Bit 11 Reset error (0-1 edge)
Bit 12 Reserved
Bit 13
Bit 14 DC braking
Bit 15 Reserved
0x400C:002
(PAR 593/002)
Predened process output data: LECOM status word
(C150)
(Old netw. o: C0150 status word)
•
Read only
Mappable status word with bit assignment in compliance with code
C150 of the 8200 Lenze inverter.
Bit 0 Acve parameter set (0 = set 1 or 3; 1 = set 2
or 4)
Bit 1 Power secon inhibited
Bit 2 Current or Torque limit reached
Bit 3 Frequency setpoint reached
Bit 4 Ramp generator (input = output)
Bit 5 Frequency < frequency threshold
Bit 6 Actual frequency = 0
Bit 7 Controller inhibit
Bit 8 Coded status bit 0
Bit 9 Coded status bit 1
Bit 10 Coded status bit 2
Bit 11 Coded status bit 3
Bit 12 Overtemperature warning
Bit 13 DC-bus overvoltage
Bit 14 Reversal
Bit 15 Ready for Operaon
Conguring the network
Predened process data words
Lenze LECOM prole
107