Parameter Name / value range / [default seng] Info
0x1201:001 SDO2 server parameter: COB-ID client -> server (RX)
0x00000000 ... [0x80000640] ... 0xFFFFFFFF
Specicaon of the receive idener for SDO server channel 2.
If SDO server channel 2 is acvated via 0x2301:005 (PAR 510/005),
this par
ameter is set to the value "node address + 0x640". This default
seng can be changed.
0x1201:002 SDO2 server parameter: COB-ID server -> client (TX)
0x00000000 ... [0x800005C0] ... 0xFFFFFFFF
Specicaon of the transmit idener for SDO server channel 2.
If SDO server channel 2 is acvated via 0x2301:005 (PAR 510/005),
this parameter is set to the value "node address + 0x5C0". This default
seng can be changed.
0x1201:003 SDO2 server parameter: SDO client node ID
1 ... [0] ... 127
Specicaon of the node address for the SDO client.
0x2301:005
(PAR 510/005)
CANopen sengs: Acvate SDO2 channel
(CANopen se.: SDO2 cong.)
1 = acvate SDO server channel 2.
0 Not acve
1 Acve
8.4.11 CANopen error responses
The response to CANopen errors such as missing PDOs or heartbeat frames can be congured
via the following parameters.
Parameter Name / value range / [default seng] Info
0x1029:000 Error behavior: Highest subindex
Read only
0x1029:001 Error behavior:
Communicaon error Selecon of the NMT state to which the inverter is to change automa-
cally if a failure of a CANopen node or an internal error is detected in the
"Operaonal" state.
These also include the following communicaon errors:
Change-over of the CAN interface to the "Bus-o" state.
Occurrence of a "Life Guarding Event".
Occurrence of a "Heartbeat Event".
0 Status -> Pre-operaonal In the "Pre-operaonal" state, network management, sync, and emer-
gency telegrams as well as parameter data can be received; process
data, however, are ignored.
1 No status change
2 Status -> Stopped In the "Stopped" state, only network management telegrams can be
received.
0x2857:001 CANopen monitoring: RPDO1-Timeout
For possible sengs see descripon for
0x2D45:001 (PAR 310/001). ^ 94
Selecon of the response to triggering the RPDO1 me monitoring.
3 Error
0x2857:002 CANopen monitoring: RPDO2-Timeout
For possible sengs see descripon for
0x2D45:001 (PAR 310/001). ^ 94
Selecon of the response to triggering the RPDO2 me monitoring.
3 Error
0x2857:003 CANopen monitoring: RPDO3-Timeout
For possible sengs see descripon for
0x2D45:001 (PAR 310/001). ^ 94
Selecon of the response to triggering the RPDO3 me monitoring.
3 Error
0x2857:005 CANopen monitoring: Heartbeat-Timeout Consumer 1
For possible sengs see descripon for
0x2D45:001 (PAR 310/001). ^
94
Selecon of the response with "Heartbeat Event" in consumer 1.
3 Error
0x2857:006 CANopen monitoring: Heartbeat-Timeout Consumer 2
For possible sengs see descripon for
0x2D45:001 (PAR 310/001). ^ 94
Selecon of the response with "Heartbeat Event" in consumer 2.
3 Error
0x2857:007 CANopen monitoring: Heartbeat-Timeout Consumer 3
For possible sengs see descripon for
0x2D45:001 (PAR 310/001). ^ 94
Selecon of the response with "Heartbeat Event" in consumer 3.
3 Error
Conguring the network
CANopen
CANopen error responses
124