Loading...
11.5 Acvang DC braking manually
By means of the "DC braking" funcon, DC braking can be acvated manually.
Precondions
The curr
ent for DC braking must be set > 0 % so that the funcon can be executed.
Parameter Name / value range / [default seng] Info
0x2631:005
(PAR 400/005)
Funcon assignment: DC braking
(Funcon lis
t: DC braking)
For possible sengs see descripon for
0x2631:001 (PAR 400/001). ^ 188
Assignment of a trigger for the "DC braking" funcon.
Trigger = TRUE: "DC braking" funcon is acvated.
Trigger = FALSE: no acon / deacvate funcon again.
4DC braking ^ 153
00 Not connected No trigger assigned (trigger is constantly FALSE).
0x2B84:001
(PAR 704/001)
DC braking: Curren
t
(DC braking: Current)
0.0 ... [0.0] ... 200.0 %
Braking current for DC braking.
100 % ≡ rated motor current 0x6075 (PAR 323)
Flexible I/O conguraon
Acvang DC braking manually
202
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: info@actechdrives.com