10.1.3 Device commands for parameter change-over
Irrespecve of the state of the funcons/triggers for this funcon, the "Parameter change-
over" funcon can also be oponally ex
ecuted with the device commands specied here.
DANGER!
Changed parameter sengs can become eecve immediately depending on the acvang
method se
t in 0x4046 (PAR 755).
The possible consequence is an unexpected response of the motor sha while the inverter is
enabled.
If possible, only carry out parameter changes while the controller is inhibited.
Certain device commands or sengs which could cause a crical state of the drive behav-
iour can generally only be carried out with controller inhibit.
Details
If acvaon method 1 or 3 is set in 0x4046 (PAR 755), the chang
e-over is eected immedi-
ately. If acvaon method 0 or 2 is set, the respecve device command is only executed if the
inverter is inhibited.
Detailed informaon about the "Parameter change-over" funcon can be found in the
"Parameter change-over" chapter. ^ 167
Parameter Name / value range / [default seng] Info
0x2022:007
(PAR 700/007)
Device commands: Load parame
ter set 1
(Device commands: Load par. set 1)
1 = load value set 1 of the "Parameter change-over" funcon.
The parameters specied in 0x4041/1...32 ar
e set to the values set in
0x4042/1...32.
Aer successful execuon, the value 0 is shown.
4Parameter chang
e-over ^ 167
0 O / ready Only status feedback.
1 On / start Execute device command.
2 In progress Only status feedback.
3 Acon cancelled
4 No access
5 No access (controller inhibit)
0x2022:008
(P
AR 700/008)
De
vice c
ommands: Load par
ame
ter set 2
(Device commands: Load par. set 2)
1 = load value set 2 of the "Parameter change-over" funcon.
The parameters specied in 0x4041/1...32 ar
e set to the values set in
0x4043/1...32.
Aer successful execuon, the value 0 is shown.
4Parameter chang
e-over ^ 167
0 O / ready Only status feedback.
1 On / start Execute device command.
2 In progress Only status feedback.
3 Acon cancelled
4 No access
5 No access (controller inhibit)
0x2022:009
(P
AR 700/009)
De
vice c
ommands: Load par
ame
ter set 3
(Device commands: Load par. set 3)
1 = load value set 3 of the "Parameter change-over" funcon.
The parameters specied in 0x4041/1...32 ar
e set to the values set in
0x4044/1...32.
Aer successful execuon, the value 0 is shown.
4Parameter chang
e-over ^ 167
0 O / ready Only status feedback.
1 On / start Execute device command.
2 In progress Only status feedback.
3 Acon cancelled
4 No access
5 No access (controller inhibit)
Addional funcons
Device Commands
Device commands f
or parameter change-over
148
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: info@actechdrives.com