10.2.4 Keypad status display
During operaon, the keypad displays the output frequency of the inverter, and in process
controller mode it show
s the process controller setpoint. Alternavely, an oponal diagnosc
parameter can be displayed during operaon.
Details
Normal display depending on the operang mode
In the default speed mode, the keypad displays the output frequency of the inverter.
If process controller mode is enabled and acve, the keypad shows the current process con-
troller setpoint in [P unit]. If process controller mode is not acve, the keypad displays the
output frequency of the inverter again.
If the inverter is working in torque mode, the keypad displays the output frequency of the
inverter.
Alternave display during operaon
In 0x2864 (PAR 703), an oponal diagnosc parameter can be set, which is to be shown on
the keypad during operaon.
In order to acvate the normal display ag
ain, 0x2864 (PAR 703) = 0 is to be set.
Parameter Name / value range / [default seng] Info
0x2864
(PAR 703)
Keypad st
atus display
(KP running indicator)
0x00000000 ... [0x00000000] ... 0xFFFFFF00
0 = normal display depending on the operang mode.
As an alternave, an oponal diagnosc parameter can be set here,
which is to be shown on the keypad during operaon.
Format: 0xiiiiss00 (iiii = hexadecimal inde
x, ss = hexadecimal subindex)
The lowest byte is always 0x00.
Keypad format: Piii.ss (iii = decimal PAR number, ss = decimal subin-
dex)
Addional funcons
Keypad
Ke
ypad status display
152