10.1 Device Commands
10.1.1 Restoring the Lenze sengs
With the "Load Lenze sengs" device command, all parameters can be reset to the Lenze
seng.
By execung this device command, all parame
ter sengs made by the user are
lost!
Details
•
All par
ame
t
er
s in the RAM memor
y of the inverter are set to the Lenze seng stored in the
rmware of the inverter. (The persistent parameters in the memory module remain unaec-
ted by this measure.)
•
Aerwards the inverter can be parameterised again on the basis of this inial state.
•
Typical applicaon: incorrect or unkno
wn parameter sengs.
Parameter Name / value range / [default seng] Info
0x2022:001
(PAR 700/001)
Device commands: Load Lenze sengs
(De
vice commands: Load Lenze se.)
•
Seng can only be changed if controller inhibit is
acve.
1 ≡ reset all parameters in the RAM memory of the inverter to the Lenze
seng that is stored in the inverter rmware.
•
All parameter changes made b
y the user are lost during this process!
•
It may take some seconds to execute the task. When the task has
been executed successfully, the value 0 is shown.
0 O / ready Only status feedback.
1 On / start Execute device command.
2 In progress Only status feedback.
3 Acon cancelled
4 No access
5 No access (controller inhibit)
Addional funcons
Device Commands
Rest
oring the Lenze sengs