10.1 Device Commands
10.1.1 Restoring the Lenze sengs
With the "Load Lenze sengs" device command, all parameters can be reset to the Lenze
seng.
By execung this device command, all parame
ter sengs made by the user are
lost!
Details
All par
ame
t
er
s in the RAM memor
y of the inverter are set to the Lenze seng stored in the
rmware of the inverter. (The persistent parameters in the memory module remain unaec-
ted by this measure.)
Aerwards the inverter can be parameterised again on the basis of this inial state.
Typical applicaon: incorrect or unkno
wn parameter sengs.
Parameter Name / value range / [default seng] Info
0x2022:001
(PAR 700/001)
Device commands: Load Lenze sengs
(De
vice commands: Load Lenze se.)
Seng can only be changed if controller inhibit is
acve.
1 ≡ reset all parameters in the RAM memory of the inverter to the Lenze
seng that is stored in the inverter rmware.
All parameter changes made b
y the user are lost during this process!
It may take some seconds to execute the task. When the task has
been executed successfully, the value 0 is shown.
0 O / ready Only status feedback.
1 On / start Execute device command.
2 In progress Only status feedback.
3 Acon cancelled
4 No access
5 No access (controller inhibit)
Addional funcons