5.3.6 Process controller status
The following parameters serve to diagnose the process controller.
Parameter Name / value range / [default seng] Info
0x401F:001
(PAR 121/001)
Process contr
oller diagnoscs: Current setpoint
(PID diagnoscs: Curr. PID setp.)
•
Read only: x.xx PUnit
Display of the current reference value (setpoint) for the process control-
ler.
0x401F:002
(PAR 121/002)
Process contr
oller diagnoscs: Current feedback
(PID diagnoscs: Curr. PID feedb.)
•
Read only: x.xx PUnit
Display of the current controlled variable (actual value) fed back for the
process controller.
0x401F:003
(PAR 121/003)
Process contr
oller diagnoscs: Status
(PID diagnoscs: PID status)
•
Read only
Bit-coded status display of the process controller.
Bit 0 Process controller o
Bit 1 Process controller output set to 0
Bit 2 Process controller I-component set to 0
Bit 3 Process controller inuence is shown via
ramp
Bit 4 Setpoint = actual v
alue
Bit 5 Idle state acve
Bit 6 Reserved
Bit 7
Related topics
4Conguring the process contr
oller ^ 138
5.3.7 Device idencaon
The following parameters show some general informaon about the inverter.
Parameter Name / value range / [default seng] Info
0x2000:001
(PAR 190/001)
Product code
(Product code)
•
R
ead only
Example: "I55AE155D10V10017S"
0x2000:002
(PAR 190/002)
Serial number
(Serial number)
•
Read only
Example: "0000000000000000XYZXYZ"
0x2000:004
(PAR 190/004)
Control unit - rmware version
(CU rmware ver.)
•
Read only
Example: "01.00.01.00"
0x2000:005
(PAR 190/005)
Control unit - rmware type
(CU rmware type)
•
Read only
Example: "IOFW51AC10"
0x2000:006
(PAR 190/006)
Control unit - bootloader version
(CU bootlder ver.)
•
Read only
Example: "00.00.00.13"
0x2000:007
(PAR 190/007)
Control unit - bootloader type
(CU bootlder type)
•
Read only
Example: "IOBL51AOnn"
0x2000:008
(PAR 190/008)
Object directory v
ersion
(OBD version)
•
Read only
Example: 108478
0x2000:010
(PAR 190/010)
Power unit - rmware version
(PU rmware ver.)
•
Read only
0x2000:011
(PAR 190/011)
Power unit - rmware type
(PU rmware type)
•
Read only
Diagnoscs and fault eliminaon
Diagnoscs
Process controller status
60