7.5 Motor rotang direcon
Parameter Name / value range / [default seng] Info
0x283A
(PAR 304)
Limitaon of rotaon
(Rotaon mode)
Oponal restricon of the rotang direcon.
0 Only for
wards The motor can only be traversed in forward direcon, since the transfer
of negave frequency and process controller setpoints to the motor con-
trol is avoided.
•
This funcon takes eect aer the "Reversal" funcon (0x2631:013
(PAR 400/013)).
•
Since this funcon only avoids negave setpoints, traversing in back-
ward direcon is possible if the motor has been wired for this rotang
direcon.
1 Forwards and backwards The motor can be traversed in both direcons.
0x2631:013
(PAR 400/013)
Funcon assignment: Reversal
(Funcon list: Reversal of rot. dir.)
•
Seng can only be changed if controller inhibit is
acve.
•
For possible sengs see descripon for
0x2631:001 (PAR 400/001). ^ 188
Assignment of a trigger for the "Reversal" funcon.
Trigger = TRUE: the setpoint specied is inverted (i. e. the sign is inver-
ted).
Trigger = FALSE: no acon / deacvate funcon again.
13 Digital input 3 State of X3/DI3, taking an inversion set in 0x2632:003 (PAR 411/003) into
consideraon.
Motor control
Motor rotang direcon
90