5 Diagnoscs and fault eliminaon
5.1 LED status displays
The "RDY" and "ERR" LED status displays on the front of the inverter provide some quick infor-
maon about certain operang states.
"RDY" LED (blue) "ERR" LED (red) Status/meaning
o o No supply voltage.
blinking (1 Hz) o Safe torque o (STO) acve.
blinking fast (4
Hz) Safe torque o (STO) acve, warning acve.
blinking (2 Hz) o Inverter inhibited.
blinking fast (4 Hz) Inverter inhibited, warning acve.
on Inverter inhibited, fault acve.
lit every 1.5 s for a
short me
Inverter inhibited, no DC-bus voltage.
on for a short me
every 1 s
Diagnosc module is connected, 5 V supply voltage for diagnosc module is available.
on on Inialisaon (inverter is started) or quick stop acve.
o Inverter enabled.
The motor rotates according to the setpoint specied.
blinking fast (4 Hz) Inverter enabled, warning acve.
The motor rotates according to the setpoint specied.
blinking (1 Hz) Inverter enabled, quick stop as response to fault acve.
66 ms o
125 ms on
66 ms on
125 ms o
Firmware update acve.
Both LEDs are ickering synchronously "Opcal detecon" funcon acve.
Diagnoscs and fault eliminaon
LED status displays