10.8 Parameter change-over
For up to 32 freely selectable parameters, this funcon provides a change-over between four
sets with dierent parame
ter values.
DANGER!
Changed parameter sengs are eecve immediately.
The possible consequence is an unexpected response of the mot
or sha while the inverter is
enabled.
If possible, only carry out parameter changes while the controller is inhibited.
Certain device commands or sengs which might cause a crical state of the drive behav-
iour can generally only be carried out with controller inhibit.
Details
The parameter list is compiled in the same way as that of the "Favorites" via parameterisa-
on. »EASY Starter« provides a user-friendly parameterisaon dialog for this purpose.
Change-over to another value set can oponally be eected via corresponding device c
om-
mands and/or special funcons/triggers:
4Device commands for parameter change-over ^ 148
4Funcons f
or parameter change-over ^ 206
Parameter Name / value range / [default seng] Info
0x2022:011
(PAR 700/011)
Device commands: Sav
e parameter set 1
(Device commands: Save par. set 1)
1 = save value set 1 of the "Parameter change-over" funcon.
When the device command has been execut
ed successfully, the value
0 is shown.
0 O / ready Only status feedback.
1 On / start Execute device command.
2 In progress Only status feedback.
3 Acon cancelled
4 No access
5 No access (controller inhibit)
0x2022:012
(PAR 700/012)
Device commands: Sav
e parameter set 2
(Device commands: Save par. set 2)
1 = save value set 2 of the "Parameter change-over" funcon.
When the device command has been execut
ed successfully, the value
0 is shown.
0 O / ready Only status feedback.
1 On / start Execute device command.
2 In progress Only status feedback.
3 Acon cancelled
4 No access
5 No access (controller inhibit)
0x2022:013
(PAR 700/013)
Device commands: Sav
e parameter set 3
(Device commands: Save par. set 3)
1 = save value set 3 of the "Parameter change-over" funcon.
When the device command has been execut
ed successfully, the value
0 is shown.
0 O / ready Only status feedback.
1 On / start Execute device command.
2 In progress Only status feedback.
3 Acon cancelled
4 No access
5 No access (controller inhibit)
Addional funcons
Paramet
er change-over
167