11.3.3 Keypad setpoint source
The following funcon is used to select the keypad as setpoint source.
Precondions
A setpoint change-over to the keypad is only eected if no setpoint source with a higher prior-
ity has been selected. 4Priority of the setpoint sour
ces^ 193
Parameter Name / value range / [default seng] Info
0x2631:016
(PAR 400/016)
Funcon assignment: Setpoint = K
eypad
(Funcon list: Setpoint=Keypad)
•
For possible sengs see descripon for
0x2631:001 (PAR 400/001). ^ 188
Assignment of a trigger for the "Setpoint = Keypad" funcon.
Trigger = TRUE: the keypad is used as setpoint source (if the trigger
assigned has the highest setpoint priority).
Trigger = FALSE: no acon / deacvate funcon again.
Notes:
•
The default keypad setpoint can be changed in keypad operang
mode via the arrow keys of the keypad.
00 Not connected No trigger assigned (trigger is constantly FALSE).
11.3.4 Network setpoint source
Generally, the network can be oponally set as standard-setpoint source or, aer correspond-
ing conguraon via a bit of the mappable NETWordIN1 data word, can be acvated as set-
point source.
Precondions
A setpoint chang
e-over to the network is only eected if no setpoint source with a higher pri-
ority has been selected. 4Priority of the setpoint sources^ 193
Details
•
In order to generally se
t the network as standard setpoint source, go to 0x2860:001
(PAR 201/001) and set the selecon "5: Network".
•
If a bit of the mappable NETWordIN1 data w
ord is to be used for acvaon, use 0x400E:001
(PAR 505/001)to assign funcon "17: Setpoint = Network" to the corresponding bit of NET-
WordIN1. 4General network sengs^ 97
•
There is no specic funcon with a selectable trigger for a setpoint change-over to the net-
work.
Flexible I/O conguraon
Setpoint change-over
Keypad setpoint sour
ce