13 Appendix
13.1 Changing the parameter sengs using the k
eypad
Keypad operang mode
Aer switching on the inverter, the keypad plugged in is in "Operang mode" aer a short
inialisaon phase.
In the operang mode,
•
the keypad can be used for local control and for manual setpoint selecon.
•
the keypad displays some informaon on the in
verter status (see the following table).
Meaning of the keypad status displays
Keypad display Display Meaning
If the inverter is inhibited, the keypad shows "STOP":
If the inverter is enabled, the ke
ypad shows the output
frequency of the inverter:
•
In PID mode, instead of the output frequency the PID
setpoin
t is shown.
•
The display can be congured in 0x2864 (PAR 703).
❶
Acve control mode:
VEL Speed mode
PID Pr
ocess controller mode
TRQ Torque mode
TSTx Test mode x
JOG Manual mode
❷
Acve control source:
FLEX Flexible I/O conguraon
KPD Keypad
NET Network
TSTx Test mode x
❸
Acve setpoint source:
AINx Analog input x
KPD Keypad
NET Network
FREQ Digital frequency
PRx Preset setpoint x
SEGx Segment x
MOP Motor potenometer
❹
Current direcon of rotaon:
FWD Motor is rotang forwards
REV Motor is rotang backwards
❺
Lower sta
tus line:
LOC Local keypad control acve.
REM Remote control via terminals, network, etc. acve.
MAN Manual setpoint selecon via keypad acve.
AUTO Automac setpoint selecon via terminals, network, etc. acve.
SET Blinking if one parameter seng has been changed but has not been
saved in the memory module with mains failur
e protecon.
Save sengs: press keypad "Enter" key > 3 s.
If a fault is pending, the keypad shows the following infor-
maon:
•
Warnings (W) are only displayed e
very 2 seconds for a
short me.
•
Trouble (T) and faults (F) are displayed connuously.
❶
Message text
❷
Response:
W Warning
T Trouble
F Fault
❸
Error code
Appendix
Changing the parameter sengs using the k
eypad
226