Funcon of the keypad keys in operang mode
Keypad display Key Funcon
Example: changing the speed setpoint while the inverter
is inhibited:
1.
2.
STOP
MAN AUTO SETLOC REM
VEL:KPD:KPD
200
MAN AUTO SETLOC REM
P202/001 Hz
If local keypad control ("LOC" display) acve: start inverter.
If remote contr
ol ("REM" display) acve: cancel stop ("KSTOP" display)
triggered via keypad again. The inverter remains stopped ("STOP" dis-
play).
Stop inverter.
Change to parameterisaon mode. See secon "Keypad parameterisa-
on mode".
Manual setpoint selecon via keypad ("MAN" display) acve:
1.
Chang
e to display and seng of the frequency se
tpoint.
2.
Incr
ease or reduce frequency setpoin
t.
Keypad parameterisaon mode
In the parameterisaon mode of the keypad you c
an have actual values of the inverter dis-
played for purposes of diagnoscs and change sengs of the inverter.
In order to provide f
or quick access, all parameters of the inverter are divided into dierent
groups according to their funcon.
Group 0 contains the congurable "Favorites". In the default seng these are the most
common parameter
s for the soluon of typical applicaons. 4Favorites ^ 162
By the hundreds digit of the PAR number (PAR Xxx) you can quickly see in which group the
parameter is to be found on the keypad:
Group/name Parameter Descripon
Group 1 - Diagnoscs PAR 1xx Diagnosc/display parameters for displaying device-internal process fac-
tors, current actual v
alues, and status messages.
4Diagnoscs ^ 44
Group 2 - basic seng PAR 2
xx Seng of the mains voltage, selecon of the control and setpoint
source, starng and stopping performance, frequency limits and ramp
mes.
4Basic seng ^ 66
Group 3 - Motor Control PAR 3xx Conguraon of the motor and motor control
4Mot
or c
on
tr
ol
^ 77
Group 4 - I/O seng PAR 4xx Funcon assignment and conguraon of the inputs and outputs
4Flexible I/O conguraon ^ 186
Group 5 - netw
ork
seng P
AR 5
xx Conguraon of the ne
tw
ork (if available)
4Conguring the network ^
96
Group 6 - Process Controller PAR 6xx Conguraon of the process controller
4Conguring the process contr
oller ^ 138
Group 7 - Addional Funcons PAR 7xx Parameterisable addional funcons
4
Addional
funcons
^
144
Appendix
Changing the parameter sengs using the k
eypad
227
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: info@actechdrives.com

Table of Contents

Other manuals for Lenze i510