10.6.1 Write access protecon
Oponally a lwrite access protecon funcon can be installed for the inverter parameters.
Details
Usually the write access protecon funcon is implemented by the mechanical engineer/
OEM , for example to pr
otect the inverter against incorrect parameterisaon by non-author-
ised persons.
Only authorised persons (who know the PIN) are then allow
ed to change all parameters of
the inverter.
Depending on the conguraon, non-authorised persons (who don't know the PIN) are not
granted write access or ar
e only allowed to change the parameters in the user menu.
All parameters are always provided with read access.
Write access protecon only restricts parameterisaon via keypad and »EASY
Starter«. Write access protecon via ne
twork is not restricted. Irrespecve of
the write access protecon that is currently set, a higher-level controller, OPC-
UA server, or any other communicaon partner connected to the inverter is
always provided with full read/write access to all parameters of the inverter.
Conguraon of the write access protecon funcon is carried out by seng PIN1 and/or
PIN2. The f
ollowing table shows the access protecon variants oered by this:
PIN1 seng PIN2 seng Log-in Status display aer
log-in
Acve write access protecon (via keypad/»EASY Starter«)
0x203D (PAR 730) 0x203E (PAR 731) 0x203F 0x2040 (PAR 197)
0 0 - 0
No access protecon congured.
> 0 0 0 or wrong PIN 2 Write access only possible to parameters of group 0 (Favor-
ites).
Correct PIN1 0 Write access to all parameters possible.
0 > 0 0 or wrong PIN 1 No write access.
Correct PIN2 0 Write access to all parameters possible.
> 0 > 0 0 or wrong PIN 1 No write access.
Correct PIN1 2 Write access only possible to parameters of group 0 (Favor-
ites).
Correct PIN2 0 Write access to all parameters possible.
»EASY Starter« provides a user-friendly parameterisaon dialog for the conguraon of the
write access protecon funcon. When the write access protecon
funcon has been acva-
ted, entry of the correct PIN1 or PIN2 in 0x203F is required in order to remove write access
protecon.
When the write access protecon funcon is acve, the keypad automacally displays an
input dialog for the PIN if a change-over to parameterisaon mode is eected. Set the PIN
using the keypad arrow keys. Aer the PIN set has been accepted by means of the keypad
"Enter" key, a short status display of the write access protecon funcon is given.
Addional funcons
Access protecon
Write access protecon
160