10.6.1 Write access protecon
Oponally a lwrite access protecon funcon can be installed for the inverter parameters.
Details
Usually the write access protecon funcon is implemented by the mechanical engineer/
OEM , for example to pr
otect the inverter against incorrect parameterisaon by non-author-
ised persons.
•
Only authorised persons (who know the PIN) are then allow
ed to change all parameters of
the inverter.
•
Depending on the conguraon, non-authorised persons (who don't know the PIN) are not
granted write access or ar
e only allowed to change the parameters in the user menu.
•
All parameters are always provided with read access.
Write access protecon only restricts parameterisaon via keypad and »EASY
Starter«. Write access protecon via ne
twork is not restricted. Irrespecve of
the write access protecon that is currently set, a higher-level controller, OPC-
UA server, or any other communicaon partner connected to the inverter is
always provided with full read/write access to all parameters of the inverter.
Conguraon of the write access protecon funcon is carried out by seng PIN1 and/or
PIN2. The f
ollowing table shows the access protecon variants oered by this:
PIN1 seng PIN2 seng Log-in Status display aer
log-in
Acve write access protecon (via keypad/»EASY Starter«)
0x203D (PAR 730) 0x203E (PAR 731) 0x203F 0x2040 (PAR 197)
0 0 - 0
No access protecon congured.
> 0 0 0 or wrong PIN 2 Write access only possible to parameters of group 0 (Favor-
ites).
Correct PIN1 0 Write access to all parameters possible.
0 > 0 0 or wrong PIN 1 No write access.
Correct PIN2 0 Write access to all parameters possible.
> 0 > 0 0 or wrong PIN 1 No write access.
Correct PIN1 2 Write access only possible to parameters of group 0 (Favor-
ites).
Correct PIN2 0 Write access to all parameters possible.
»EASY Starter« provides a user-friendly parameterisaon dialog for the conguraon of the
write access protecon funcon. When the write access protecon
funcon has been acva-
ted, entry of the correct PIN1 or PIN2 in 0x203F is required in order to remove write access
protecon.
When the write access protecon funcon is acve, the keypad automacally displays an
input dialog for the PIN if a change-over to parameterisaon mode is eected. Set the PIN
using the keypad arrow keys. Aer the PIN set has been accepted by means of the keypad
"Enter" key, a short status display of the write access protecon funcon is given.