»EASY Starter« funcons aected by write access protecon
The following »E
ASY Starter« funcons are not supported when write access protecon is
acve:
•
Parameter se
t download
•
Manual check of motor rotang direcon
•
Denion of the user menu parameters
•
Denion of the parameters for the "Parameter change-over" funcon
•
Deleon of the logbook entries
The following »EASY Starter« funcons are supported irrespecve of whether write access
protecon is acve:
•
Opcal device idencaon0x2021:001 (PAR 230/001)
•
Enable/inhibit in
verter0x2822:001
•
Start/stop program
•
Reset parameter to the Lenze seng0x2022:001 (PAR 700/001)
•
Save parameter set 0x2022:003 (PAR 700/003)
•
Load user parameter 0x2022:004 (PAR 700/004)
•
Load OEM parameter 0x2022:005 (PAR 700/005)
•
Reset error 0x2631:004 (PAR 400/004)
Parameter Name / value range / [default seng] Info
0x203D
(PAR 730)
PIN1 access protecon
(PIN1 protecon)
-1 ... [0] ... 9999
PIN denion for write access
protecon.
•
1 … 9999 = set/change PIN.
•
0 = delet
e PIN (deacvate access protecon).
•
When the PIN has been set successfully, the value -1 is shown; other-
wise 0.
•
Seng/changing the PIN via keypad/»EASY Starter« only possible if
no write access protecon is acve.
•
Sengs/changes via »EASY Start
er« become eecve immediately;
via keypad they only become eecve when the parameter group has
been exited.
0x203E
(PAR 731)
PIN2 access protecon
(PIN2 protecon)
-1 ... [0] ... 9999
PIN2 for write access protecon.
PIN1 for write access protecon.
•
1 … 9999 = set/change PIN.
•
0 = delet
e PIN (deacvate access protecon).
•
When the PIN has been set successfully, the value -1 is shown; other-
wise 0.
•
Seng/changing the PIN via keypad/»EASY Starter« only possible if
no write access protecon is acve.
•
Sengs/changes via »EASY Start
er« become eecve immediately;
via keypad they only become eecve when the parameter group has
been exited.
•
1 … 9999 = set/change PIN.
•
0 = delete PIN (deacvate access protecon).
•
When the PIN has been set successfully, the value -1 is sho
wn; other-
wise 0.
•
Seng/changing the PIN via keypad/»EASY Starter« only possible if
no write access protecon is acve.
•
Sengs/changes via »EASY Start
er« become eecve immediately;
via keypad they only become eecve when the parameter group has
been exited.
0x203F PIN1/PIN2 log-in
-32768 ... [0] ... 32767
Parameter for PIN entry for the purpose of deacvang an acve access
protecon.
•
1 … 9999 = log-in (deacvate access protecon).
•
0 = log-out (reacvate access protecon).
•
Aer having logged in successfully, the value 0 is shown; otherwise -1.
•
Aer 10 invalid entries, the log-in funcon is inhibited. In order to
remove the log-in inhibit, the inverter must be switched o and on
again.
0x2040
(PAR 197)
Access protecon status
(Protecon status)
•
Read only
Display of the acve access protecon aer log-in via PIN1/PIN2.
•
0 = write access to all parameters possible.
•
1 ≡ no write access.
•
2 = write access only possible to parameters of group 0 (Favorites).
Addional funcons
Access protecon
Write access protecon
161